A CAVITATION WEAR ON CENTRIFUGAL PUMP IMPELLENTS MADE FROM HASTELLOY C-276 ALLOY

  • Isnel Rodriguez Gonzalez Universutary Professor
  • Tomás Fernánde- Columbié Universidad de Moa “Dr. Antonio Núñez Jiménez”. Ave. Calixto García #15, entre Ave. 7 de Diciembre y calle Reynaldo Laffita, Las Coloradas, Moa. Holguín. Mechanical Department.
  • Jorge Luis Reyes-de la Cruz Universidad de Moa “Dr. Antonio Núñez Jiménez”. Ave. Calixto García #15, entre Ave. 7 de Diciembre y calle Reynaldo Laffita, Las Coloradas, Moa. Holguín. Mechanical Department.
  • Ledennis Suárez- Torres Universidad de Moa “Dr. Antonio Núñez Jiménez”. Ave. Calixto García #15, entre Ave. 7 de Diciembre y calle Reynaldo Laffita, Las Coloradas, Moa. Holguín. Mechanical Department.
Keywords: cavitation, blades, wear, leached liquor, Hastelloy C-276

Abstract

This article establishes the incidence of the leached liquor in the wear, by cavitation, of impellers of a centrifugal pump. The impeller blades, manufactured from the Hastelloy C-276 superalloy, were analyzed. Eight samples which were sectioned from the upper end of the blade, less affected, to the tip of the blade, more damaged. Through scanning electron microscopy (SEM), pitting, rupture of the passive layer, crumbling of the structure, as well as intercrystalline corrosion were evidenced on the surface. It was observed, in diffractograms, the presence of chlorine (Cl), chemical element that forms chloride ions, which prevents the formation of stable layers of oxides. As a result of this phenomenon, the hardness increased from 225 HV to 270 HV, after the analyzed impellers were removed from service.

Downloads

Download data is not yet available.

References

Alcántara, D., Fernández, T. y Rodríguez, I. (2016). Influence of leached pulp on wear of a Hastelloy C-276. Minería y Geología, 32 (1), 93-105.

Barzdaitis, V., Mažeika, P., Vasylius, M., Kartašovas, V. y Tadžijevas, A. (2016). Investigation of pressure pulsations in centrifugal pump system. Journal of Vibroengineering, 50 (7), 650-658.

Durán-Martínez, W. y Fernández-Columbié, T. (2018). Effect of corrosion wear on a superalloy exposed to a high concentration of elements in the fluid. Ciencia & Futuro, 8 (3), 20-31.

Friedrichs, J. y Kosyna. G. (2002). Rotating cavitation in a centrifugal pump impeller of low specific speed. Journal of Fluids Engineering, 124 (6), 356-362.

Guo, X., Zhu, Z., Cui, B. y Shi, G. (2016). Effects of the number of inducer blades on the anti-cavitations characteristics and external performance of a centrifugal pump. Journal of Mechanical. Science and Technology, 3 (17), 67-75.

Meng, H. y Ludema K. (1995). Wear models and predictive equations: their form and content. Wear. 181 (183), 443-457.

Mittag, S. y Gabi, M. (2015). Experimental and numerical investigation of centrifugal pumps with asymmetric in flow conditions. Journal of Thermal Science, 12 (4): 34-41.

Reyes, J. (2007). Diagnosis of hydro-mixture transport facilities affected by cavitation. Minería y Geología, 23 (3), 87-117.

Reyes, J. (2010). A teaching and research experiment of cavitation in centrifugal pumps. American Association of Teachers of Physics. Lat. Am. J. Phys. Educ, 4 (I), 2-18.

Reyes, J. (2015). Saturation pressure of ammonia liquor and its relation to cavitation in centrifugal pumps. Minería y Geología, 31 (1), 23-30.

Reyes-Cruz, J., Fernández-Columbié, T., Rodríguez-González, I., Ruíz-Chavarría, G. y Hernández-Zapata, S. (2019). Effect of bubble implosion on cavitation wear of centrifugal pumps transferring ammonia fluids. Minería y Geología, 35 (3), 327-337.

Shi, W., Li, T., Zhang, D. (2013). Effect of tip clearance on the cavitations and flow field of axial flow pumps. Journal of Huazhong University of Science and Technology: Natural Science Edition, 41 (4): 21-25.

Stechmann, D.; Sese, C., Duvvur, R.; Zhang, A. y Pourpoint, T. (2015). Design and analysis of a high-pressure turbopump at purdue university 51st AIAA/SAE/ASEE. Joint Propulsion Conference, 24 (13), 76-84.

Xiao, L., Li, Y., Liu, Y., Bi, Z. y Zhao, W. (2016). Effect of wearing clearance on cavitation flow and performance of centrifugal pump with inducer. Journal of Drainage and Irrigation Machinery Engineering, 3 (2), 57- 65.

Published
2021-05-25
How to Cite
Rodriguez Gonzalez, I., Columbié, T. F.-, Cruz, J. L. R.- de la, & Torres, L. S.-. (2021). A CAVITATION WEAR ON CENTRIFUGAL PUMP IMPELLENTS MADE FROM HASTELLOY C-276 ALLOY. IJRDO - Journal of Mechanical And Civil Engineering, 7(5), 19-24. https://doi.org/10.53555/mce.v7i5.3957